The Wine Guardian DP50 specifications below are the manufacturer's published figures for the 60 Hz unit, including the full net-cooling ladder by condenser inlet air temperature, measured with the cellar held at 57°F and 55% relative humidity. Capacity falls as the air entering the condenser gets warmer, so read the row that matches the space the unit will exhaust into rather than a single headline number.
ModelDP50
SeriesWine Guardian Pro, Sentinel Series chassis
Line frequency60 Hz
Rated cooling capacity2,700–6,320 BTU/h (Wine Guardian published range)
Cooling at 80°F condenser inlet air6,320 BTU/h total (cellar 57°F / 55% RH)
Nominal compressor0.50 HP
Recommended cellar volume650–3,000 ft³
Storage temperature range52°F to 70°F (Wine Guardian published range for the Ducted Pro line)
Humidity (with optional humidifier)55% to 65%
Control accuracy±1°F / ±10% RH
RefrigerantR-134A
Electrical115 V, single phase, 60 Hz: the DP50 is the largest Ducted Pro model that runs on a standard 115 V circuit
Condenser inlet air operating range45°F to 95°F
Evaporator / condenser fan motor100 W
Current draw (cooling)11.3 A
Current draw (heating)9.6 A
Minimum circuit ampacityRead the value from the current Wine Guardian Ducted Pro specifications sheet and have a licensed electrician size the circuit
Electric heat optionAvailable as a factory option; confirm the wattage and circuit requirement on the Wine Guardian Ducted Pro specifications sheet with a licensed electrician
Dimensions (L x W x H)41.5 in x 22.5 in x 19 in
Weight125 lbs
Condensate drain connection0.50 in inside diameter, pitched 0.25 in per linear foot, no external trap
Minimum ductwork size10 in evaporator side, 8 in condenser side
Maximum recommended duct run25 ft cumulative, supply plus return, including bends
Agency approvalETL listed, UL 1995 / CSA C22.2
Cabinet constructionAluminum chassis with UL-rated composite panels
Net cooling at 60°F condenser inlet (cellar 57°F / 55% RH)6,920 BTU/h
Net cooling at 70°F condenser inlet (cellar 57°F / 55% RH)6,570 BTU/h
Net cooling at 80°F condenser inlet (cellar 57°F / 55% RH)6,320 BTU/h
Net cooling at 90°F condenser inlet (cellar 57°F / 55% RH)5,860 BTU/h
Net cooling at 110°F condenser inlet (cellar 57°F / 55% RH)4,865 BTU/h
Net cooling at 120°F condenser inlet (cellar 57°F / 55% RH)4,585 BTU/h