The Wine Guardian DP25 is a 115 V, 60 Hz self-contained ducted unit with a 0.33 HP nominal compressor, R-134a refrigerant and a rated capacity of 3,760 BTU/h at 80°F condenser inlet air. Wine Guardian publishes two complete performance tables for this model, and both are reproduced below.
ModelDP25 (Pro ducted)
SeriesSentinel Series, Pro ducted tier
ConfigurationSelf-contained, fully ductable, air-cooled
Line frequency60 Hz
Rated cooling capacity3,760 BTU/h at 80°F condenser inlet air, 115 V (return air 57°F / 55% RH)
Second published rating basis5,080 BTU/h at 80°F condenser inlet air, 115 V (return air 80°F / 50% RH)
Nominal compressor0.33 HP
Recommended space volume250 to 2,000 ft³
Storage temperature range (Pro ducted line)52°F to 70°F
Humidity, with optional humidifier55% to 65% RH
Safe condenser inlet air range45°F to 95°F
Low ambient protectionStandard. Protects the system from cold temperatures below 40°F
RefrigerantR-134a
Electrical115/1/60, single voltage
Current draw, cooling7.1 A
Evaporator fan motor75 W
Rated airflow, free blow245 CFM
Minimum circuit ampacity and overcurrent protectionNot published on this page. Read the Wine Guardian specifications sheet and have a licensed electrician size the circuit
Electric heatAvailable as a factory option. Wattage not published on this page; see the Wine Guardian specifications sheet
Dimensions (L x W x H)33.45 in x 16.6 in x 15.56 in
Weight78 lbs (Wine Guardian's Pro ducted specifications sheet and installation manual print 80 lbs for this model)
Condensate drain connection0.50 in inside diameter, gravity drain at 1/4 in of pitch per linear foot
Drain trapBuilt-in internal trap. Wine Guardian instructs that no external trap is installed
Minimum ductwork, evaporator side8 in round
Minimum ductwork, condenser side6 in round
Agency approvalApproved by ETL according to UL 1995 and CSA safety standards
Cabinet constructionAll-aluminum chassis with UL-rated composite panels
Sound ratingWine Guardian publishes no decibel rating for its ducted units
Warranty25 months parts, 13 months labor
Net cooling at 60°F condenser inlet (57°F / 55% RH)4,520 BTU/h
Net cooling at 70°F condenser inlet (57°F / 55% RH)4,300 BTU/h
Net cooling at 80°F condenser inlet (57°F / 55% RH)3,760 BTU/h
Net cooling at 90°F condenser inlet (57°F / 55% RH)3,540 BTU/h
Net cooling at 110°F condenser inlet (57°F / 55% RH), excursion outside the 45°F to 95°F operating range3,260 BTU/h
Net cooling at 120°F condenser inlet (57°F / 55% RH), excursion outside the 45°F to 95°F operating range3,000 BTU/h
Net cooling at 60°F condenser inlet (80°F / 50% RH)5,980 BTU/h
Net cooling at 70°F condenser inlet (80°F / 50% RH)5,570 BTU/h
Net cooling at 80°F condenser inlet (80°F / 50% RH)5,080 BTU/h
Net cooling at 90°F condenser inlet (80°F / 50% RH)4,425 BTU/h
Net cooling at 110°F condenser inlet (80°F / 50% RH), excursion outside the 45°F to 95°F operating range4,070 BTU/h
Net cooling at 120°F condenser inlet (80°F / 50% RH), excursion outside the 45°F to 95°F operating range3,780 BTU/h
Rating footnoteAll ratings at sea level