Wine Guardian rates the D200 at 15,350 BTU/h on 208 V and 15,680 BTU/h on 230 V at 80°F condenser inlet air, and publishes net capacity at 60°F, 70°F, 80°F and 90°F condenser inlet air for both voltages.
ModelD200
SeriesSentinel Series
ConfigurationDucted, self-contained, air-cooled
Line frequency60 Hz
Electrical208-230/1/60
Rated cooling capacity at 80°F condenser inlet air15,350 BTU/h at 208 V; 15,680 BTU/h at 230 V
Capacity rating basisWine Guardian: "Cooling capacity rated at 80°F ambient"
Published capacity range8,000 to 15,680 BTU/h
Recommended cellar volume1,500 to 7,000 ft³
Net cooling at 60°F condenser inlet air17,570 BTU/h at 208 V; 17,680 BTU/h at 230 V
Net cooling at 70°F condenser inlet air16,580 BTU/h at 208 V; 16,720 BTU/h at 230 V
Net cooling at 80°F condenser inlet air15,350 BTU/h at 208 V; 15,680 BTU/h at 230 V
Net cooling at 90°F condenser inlet air14,000 BTU/h at 208 V; 15,000 BTU/h at 230 V
Net cooling at 110°F and 120°F condenser inlet airNot rated; Wine Guardian prints N/A for the D200 at both conditions
Safe operating range, condenser inlet air temperature45°F to 95°F per the Wine Guardian ducted installation manual
Evaporator entering conditions for the ratings57°F and 55% RH at rated airflow
Storage temperature range55°F to 58°F
Humidity with optional Wine Guardian humidifier55% to 65%
Control accuracy±1°F / ±10% RH
RefrigerantR-134A
Evaporator / condenser fan motor160 W at 208/1/60; 180 W at 230/1/60
Current draw (cooling)15.6 A at 208 V; 14.1 A at 230 V
Minimum circuit ampacity and electric heat optionTake these from the Wine Guardian ducted specifications sheet and have a licensed electrician confirm them
Dimensions (L x W x H)41.5 in x 22.5 in x 19 in
Weight206 lbs
Condensate drain connection0.50 in, pitched 0.25 in per linear foot to an open floor drain or condensate pump
Minimum ductwork size12 in round
Maximum flexible duct run25 ft cumulative, supply and return combined, including bends
Service clearance3 ft minimum
Agency approvalETL listed, UL 1995 / CSA C22.2
Cabinet constructionAluminum chassis with UL-rated composite panels
Wine Guardian's ducted specifications sheet prints minimum circuit ampacity and the electric heat option in combined cells that we do not reproduce here. Take both figures from the manufacturer's sheet and have a licensed electrician size the circuit and overcurrent protection to national and local codes.