Free sizing consultation · Call 1-800-260-1712

Designing a wine cellar?

Free expert consultation on sizing and setup.

Wine Guardian D025WC Water Cooled Wine Cooling Unit

Wine Guardian  |  SKU: 99H0254-20
$6,795.00

Call Us At 1 (800) 260-1712 Or Chat Now To UNLOCK THE BEST PRICE AVAILABLE!

Cooling Unit Options

Options:

*All Wine Temperatures Bundle

For extended wine-cellar temperature ranges. Allows a Wine Guardian unit to control to an extended temperature range from 45°F to 64°F, perfect for single to multiple cabinet applications and small wine rooms in which serving-temperature cooling is preferred.

This bundle also contains an integral electric heater coil and controls to protect wine cellars from dangerously low temperatures. It is ideal for areas where ambient temperatures fall below 50°F.

Ships direct from Wine Guardian

Tracking is provided when the order ships from Wine Guardian

THINKING ABOUT THE PERFECT WINE CELLAR? Save time and money: get expert advice before you buy

Call our Wine Cellar Specialist at 1 (800) 260-1712 for FREE CONSULTATION!

SENTINEL SERIES · Water-Cooled Ducted

D025WC Water-Cooled Ducted Unit for Wine Cellars up to 2,000 Cubic Feet

The Wine Guardian D025WC water-cooled ducted unit is a self-contained wine cellar cooling system that Wine Guardian rates at a maximum capacity of 3,760 BTU/h and that rejects its heat into a building water loop instead of into the surrounding air.

That single difference is the whole decision. A water-cooled unit exists for the case where there is nowhere acceptable to send warm exhaust air: a sealed mechanical room, a finished basement with no route to outside, a space where the heat would land somewhere it is not wanted, or a build where the noise and airflow of a condenser fan cannot go, a constraint our comparison of every location in a home where a wine cellar can be built works through room by room. In exchange the heat has to go somewhere else, and that somewhere is a water loop the building already has. Wine Guardian names geothermal, cooling tower and lake water as the applications these systems are built for, and states that water-cooled systems remove the need to exhaust heat but require a year-round water supply. Specifying the D025WC is therefore a plumbing and building-services decision before it is a cooling decision.

Wine Guardian publishes a safe condenser inlet water temperature range of 45°F to 85°F and warns that water entering above 85°F risks tripping the high-pressure switch. It does not recommend a water-cooled system on a city water supply, and it specifies copper straight tube connections for both the cooling water inlet and the outlet. The water side of the 025 is published in full: the ducted specifications sheet carries a Water-cooled Condenser Section block with its own D025 column giving 0.50 GPM, a 0.20 PSI pressure drop and a 0.50 inch outside-diameter connection, so the loop can be checked against real numbers before anything is ordered.

The D025WC is a single-voltage unit: Wine Guardian publishes one supply for it, 115 V single phase at 60 Hz, with no 208 V or 230 V alternative to choose between. It is sized for wine cellars and wine rooms of 250 to 2,000 cubic feet and holds them at 55°F to 58°F. Every unit ships with a coated evaporator coil, a Wireless2Base remote interface controller, an aluminum chassis with UL-rated composite panels and Wine Guardian fail-safe protection. As an authorized Wine Guardian dealer we list the D025WC with full manufacturer specifications so it can be compared and sized correctly; final sizing should be confirmed with the Wine Guardian cooling calculator and a licensed HVAC professional.

3,760 BTU/h
Maximum Capacity
45–85 °F
Entering Water Range
250–2,000 ft³
Cellar Volume
115 V
Single Supply Voltage
See It in Action

See the D025WC in Action

Where the Heat Actually Goes

See how a Wine Guardian water-cooled system carries cellar heat out through a water loop instead of blowing it into an adjacent room.

  • Heat rejected to water, so no warm-air exhaust has to be routed anywhere
  • Suits sealed mechanical rooms and spaces with no path to outside air
  • Requires a year-round water supply that the building already has

Questions about fit? Call our specialists at (800) 260-1712.

Fit Check

Is the D025WC Water-Cooled Unit Right for Your Small Wine Cellar?

The D025WC is the right unit when a cellar of 250 to 2,000 cubic feet has no acceptable place to reject heat into the air and the building already has a year-round water loop to reject it into instead. If that loop does not exist yet, the honest comparison is not against another cooling unit but against the cost of building the loop, and in most homes the air-cooled D025 is the simpler answer. Wine Guardian itself frames the move up to the D025WC as a fit question rather than a performance one: it recommends the D025WC where a cellar sized for a TTW018 contains a lot of glass or additional internal heat sources and a year-round water source is available.

✓ Ideal For

  • Sites with an existing geothermal loop, cooling tower or lake water source, the applications Wine Guardian names for its water-cooled systems
  • Small residential and commercial wine cellars and wine rooms of 250 to 2,000 cubic feet
  • Sealed mechanical rooms, interior spaces and finished basements with no route for warm exhaust air
  • Rooms sized for a through-the-wall unit that carry a lot of glass or extra internal heat, which is the case Wine Guardian names for moving up to the D025WC
  • Projects where a licensed contractor is already making refrigeration, electrical and plumbing connections
  • Installs that can route insulated ductwork to a unit located outside the cellar

✕ Consider Another Model If

  • There is no water loop on site, in which case the air-cooled D025 does the same cooling with no plumbing
  • Your only water source is a metered city supply, which Wine Guardian does not recommend for water-cooled systems
  • The available water is seasonal, shared with another load, or cannot be held between 45°F and 85°F all year
  • The loop cannot spare 0.50 GPM at the unit alongside whatever else it already serves
  • Your cellar is larger than 2,000 cubic feet, where the D050WC is the water-cooled step up
  • You need a 208 V or 230 V supply, since the D025WC is published at 115 V only
Key Features

D025WC Key Features

The D025WC pairs the standard Sentinel Series ducted platform with a factory-configured water-cooled condenser section, so everything below the heat-rejection rows is shared with the air-cooled D025.

Feature What it means for your cellar
Water-cooled condenser section Heat leaves through a water loop rather than a condenser air stream, so no room has to absorb the exhaust. The loop must already exist and must run all year.
Factory-configured water-cooled condensing coil and water-regulating valve Wine Guardian builds the water side into the unit rather than leaving it to be assembled on site, and the regulating valve meters loop flow to the load instead of running wide open.
Copper straight tube water connections, 0.50 in outside diameter Cooling water inlet and outlet are copper straight tube, so the connection is made by the plumbing or mechanical trade during installation, not by the owner afterwards.
Self-contained ducted design Evaporator, fans, compressor, condenser and controls sit in one cabinet outside the cellar, so the wine room itself stays quiet and clear.
Coated evaporator coil Protects the evaporator side against corrosion in the humid air a wine cellar is deliberately kept in.
Wireless2Base remote interface controller Monitors temperature and humidity continuously and corrects conditions before the wine is affected; the controller can be placed in a kitchen, den or elsewhere.
Precision control (±1°F / ±10% RH) Holds wine-storage conditions of 55°F to 58°F, with an optional humidifier for 55% to 65% relative humidity.
Aluminum chassis with UL-rated composite panels Resists dents and scratches through shipping and installation, and keeps the cabinet serviceable in a mechanical room.
Field-serviceable, multi-panel access Panels, duct collars and grille remove with a couple of screwdriver turns, so service happens on site rather than by returning the unit.
Optional bundles and humidification Wine Guardian lists an All Wine Temperatures Bundle, which extends control to 45°F to 64°F with an integral heater, plus integrated and freestanding humidifiers.

What the Water Loop Must Supply

Wine Guardian publishes the water side of the D025WC in numbers. The ducted specifications sheet carries a block headed Water-cooled Condenser Section (option) with one column per D model, and the D025 column reads 0.50 GPM, 0.20 PSI and 0.50 inches. The ducted installation and operation manual independently lists the water out and water in connections at 0.50 inch outside diameter, which corroborates that column. Alongside those figures Wine Guardian publishes two hard requirements: a condenser inlet water temperature inside a safe operating range of 45°F to 85°F, and a year-round water supply. It warns that water entering above 85°F risks tripping the high-pressure switch, does not recommend water-cooled systems on a city water supply, and specifies copper straight tube connections for the cooling water inlet and outlet. Have the installing contractor confirm the loop can actually deliver 0.50 GPM at the unit alongside everything else it serves.

Built-in protection: the system checks conditions continuously through remote air sensing and adjusts before temperature or humidity drift can affect the collection.

How Quiet Is It

How Quiet Is the D025WC?

Why a Water-Cooled Ducted Unit Keeps the Cellar Quiet

Wine Guardian does not publish a decibel rating for its ducted units, because the dominant noise factor is placement: the D025WC installs outside the wine room and connects through insulated ductwork, so the compressor and fans are not in the space you occupy. Rejecting heat to water rather than air also removes the condenser air stream that a comparable air-cooled unit has to move and exhaust somewhere.

  • The unit sits in a utility room, closet or adjacent space, away from the cellar.
  • Internal components are mounted on rubber-in-shear isolators to reduce vibration and noise.
  • Flexible ductwork absorbs air noise, and sound drops further each time a duct run turns a corner.
  • There is no condenser exhaust airflow to find a home for, which is often the noise complaint on an air-cooled install.
Full Specifications

Wine Guardian D025WC Water-Cooled Specifications

Wine Guardian publishes the D025 platform in a single voltage column, 115 V single phase at 60 Hz, so unlike the D088 and D200 classes there is no second voltage to choose between and every capacity figure below belongs to that one supply. The capacity ladder is published on the Wine Guardian ducted specifications sheet against condenser inlet air temperature, in the manufacturer's own wording, and each row is given as total and sensible capacity. The water side is published separately in the sheet's Water-cooled Condenser Section (option) block. No 100°F row is printed on the sheet, so none is shown here.

ModelD025WC
SeriesSentinel Series
ConfigurationSelf-contained ducted, water-cooled condenser section
Heat rejectionTo a building water loop
Condenser inlet water temperature (safe operating range)45°F to 85°F
Water supplyYear-round supply required; city water not recommended by Wine Guardian
Water connectionsCopper straight tube, cooling water inlet and outlet
Water flow rate0.50 GPM (Water-cooled Condenser Section option, D025 column, Wine Guardian ducted specifications sheet)
Water-side pressure drop0.20 PSI (same source and column)
Water connection size0.50 in outside diameter, inlet and outlet
Manufacturer maximum capacity3,760 BTU/h (0.97 kW), as published by Wine Guardian for the D025WC
Published measurement conditionNet cooling capacity at entering temperature and humidity conditions of 57°F and 55% RH at rated airflow; all ratings at sea level
Net cooling at 60°F condenser inlet air4,520 BTU/h total, 3,050 BTU/h sensible, at 115 V
Net cooling at 70°F condenser inlet air4,300 BTU/h total, 2,915 BTU/h sensible, at 115 V
Net cooling at 80°F condenser inlet air3,760 BTU/h total, 2,715 BTU/h sensible, at 115 V
Net cooling at 90°F condenser inlet air3,540 BTU/h total, 2,580 BTU/h sensible, at 115 V
Net cooling at 110°F condenser inlet air3,260 BTU/h total, 2,400 BTU/h sensible, at 115 V
Net cooling at 120°F condenser inlet air3,000 BTU/h total, 2,260 BTU/h sensible, at 115 V
Recommended cellar volume250–2000 ft³, as published by Wine Guardian
Storage temperature range55°F to 58°F
Humidity (with optional humidifier)55% to 65%
Control accuracy±1°F / ±10% RH
RefrigerantR-134A
Electrical115/1/60, single voltage only
Line frequency60 Hz
Current draw (cooling)7.1 A at 115 V
Minimum circuit ampacitySee the Wine Guardian ducted specifications sheet; have a licensed electrician size the circuit
Electric heat optionSee the Wine Guardian ducted specifications sheet; have a licensed electrician size the circuit
Evaporator fan motor75 W
Dimensions (L x W x H)33.45 in x 16.6 in x 15.56 in
Weight78 lbs
Condensate drain connection0.50 in
Minimum ductwork size8 in round
Agency approvalUL 1995 / CSA C22.2
Cabinet constructionAluminum chassis with UL-rated composite panels

Minimum circuit ampacity and the electric heat rating are printed on the Wine Guardian ducted specifications sheet as combined heat and no-heat values in a single cell and are not reproduced here. Take both from that sheet and have a licensed electrician size the circuit, the disconnect and the overcurrent protection.

Compatible Accessories

Compatible D025WC Accessories

Accessory availability and pricing are confirmed on each live product page. An integrated or freestanding Wine Guardian humidifier can be added to reach 55% to 65% relative humidity. Water-loop piping, valves and any circulator are supplied and installed by the contractor making the connection.

Compare Across the Line

How the D025WC Compares to the D050WC and the Air-Cooled D025

The D025WC and the air-cooled D025 are the same cooling platform; they differ only in where the heat goes and what the building must already provide. The D050WC is the next water-cooled size up.

Decision factor D025WC (water-cooled) D025 (air-cooled) D050WC (water-cooled)
Where the heat goes Into a building water loop Into the surrounding air Into a building water loop
What the site must already have A year-round water supply entering between 45°F and 85°F A space that can absorb and ventilate the exhaust heat A year-round water supply entering between 45°F and 85°F
Trades needed to install Refrigeration, electrical and plumbing Refrigeration and electrical Refrigeration, electrical and plumbing
Wine Guardian published maximum capacity 3,760 BTU/h 4,300 BTU/h 6,320 BTU/h

Read the capacity row carefully. Wine Guardian publishes the D025WC and the air-cooled D025 from the same D025 column of the ducted specifications sheet, and quotes the two at different condenser inlet air temperatures: 4,300 BTU/h is that column's 70°F row and 3,760 BTU/h is its 80°F row. The gap is a difference in the published condition, not a difference in the platform. The D050WC figure is the one Wine Guardian publishes on its water-cooled ducted line page.

Best for: choose the D025WC if a cellar of 250 to 2,000 cubic feet has nowhere acceptable to reject heat into the air and a year-round water loop is already on site. Not ideal for: choose the air-cooled D025 if a ventilated space is available, because it is the same platform with no water connection and one fewer trade; choose the D050WC if the room is beyond what the 025 class covers.

If you are still choosing a configuration, the full range of Wine Guardian water-cooled ducted cooling systems shows every capacity that rejects heat to a loop, and if you are working from room size instead, compare it against the other cooling units for cellars of 1,200 to 2,200 cubic feet.

In the Box

What's Included

The D025WC self-contained water-cooled ducted cooling unit
Factory-configured integral water-cooled condensing coil and water-regulating valve
Copper straight tube cooling water inlet and outlet connections, 0.50 in outside diameter
Wireless2Base remote interface controller
Integral controls and air-sensing technology
Manufacturer documentation and quick-start guide
Frequently Asked Questions

D025WC Water-Cooled System Questions

What does the D025WC need from the building water loop?
The D025WC needs a year-round supply of water entering the condenser between 45°F and 85°F. Wine Guardian's ducted installation and operation manual states that the safe operating range of the condenser inlet water temperature is 45°F to 85°F, and its water-cooled brochure states that water-cooled systems remove the need to exhaust heat but require a year-round water supply. Wine Guardian names geothermal, cooling tower and lake water as the applications these systems are built for.
Can the D025WC run on city water?
Wine Guardian does not recommend it. Its ducted installation and operation manual states that it does not recommend using a water-cooled system if you are using a city water supply. Plan the D025WC around a recirculating or natural water source such as a geothermal loop, a cooling tower or lake water rather than a metered municipal line.
What happens if the water runs too warm or the supply is interrupted?
Warm or missing water stops the cooling before the cellar does. Wine Guardian warns that if the water temperature entering the unit is above 85°F you risk tripping the high-pressure switch, and it specifies a year-round water supply, so a loop that is seasonal, shared with another load or throttled will not hold the room. A licensed HVAC professional should confirm the loop can keep entering water within 45°F to 85°F in every season before the unit is specified.
How much water does the D025WC use, and what size line does it need?
Wine Guardian publishes the D025 water side on the ducted specifications sheet, in a block headed Water-cooled Condenser Section (option) that carries its own D025 column: 0.50 GPM, a 0.20 PSI pressure drop and a 0.50 inch outside-diameter connection. The ducted installation and operation manual independently lists the water in and water out connections at 0.50 inch outside diameter. Have the installing contractor confirm the loop can deliver that flow alongside whatever else it serves.
Who is qualified to connect the D025WC to a water loop?
A licensed contractor. Wine Guardian states on the D025WC product page that contractor installation is recommended, and its ducted installation and operation manual specifies copper straight tube connections for both the cooling water inlet and the outlet, so the connection is plumbing and building-services work carried out alongside the refrigeration and electrical installation. Wine Guardian documentation and a licensed HVAC professional or qualified contractor should confirm the final installation design.
How much cooling does the D025WC provide, and for what size cellar?
Wine Guardian states that the maximum capacity of this system is 3,760 BTU/h and recommends the D025WC for wine cellars of 250 to 2,000 cubic feet. On the ducted specifications sheet the D025 column gives 3,760 BTU/h total and 2,715 BTU/h sensible at an 80°F condenser inlet air temperature, published as net cooling capacity at entering temperature and humidity conditions of 57°F and 55% RH at rated airflow, at sea level. Final sizing should be confirmed with the Wine Guardian cooling calculator and a licensed HVAC professional.
What voltage and electrical circuit does the D025WC need?
The D025WC is a single-voltage unit. Wine Guardian publishes one supply for it, 115 V single phase at 60 Hz, with no 208 V or 230 V alternative, and gives the running current draw in cooling as 7.1 A. The minimum circuit ampacity and the electric heat rating are printed on the Wine Guardian ducted specifications sheet as combined heat and no-heat values, so they are not reproduced here; take both from that sheet and have a licensed electrician size the circuit, the disconnect and the overcurrent protection.
How is the D025WC different from the air-cooled D025?
The D025WC rejects its heat into a water loop instead of into the surrounding air. Wine Guardian describes the D025WC as the D025 with a factory-configured integral water-cooled condensing coil and water-regulating valve, so the difference is not the cooling platform but where the heat goes and what the building has to provide. The air-cooled D025 needs a space that can absorb and ventilate the exhaust heat; the D025WC needs a year-round water loop that is already there.
Does the D025WC control humidity?
The D025WC controls temperature precisely and displays humidity. To actively raise humidity to 55% to 65% relative humidity, add an integrated or freestanding Wine Guardian humidifier, which connects to the system.
Is the D025WC covered by a warranty?
Yes. Wine Guardian provides a standard warranty of 25 months on parts and 13 months on labor. A Platinum option extends coverage to 25 months on parts and labor plus a 36-month parts-only extension on the compressor, evaporator coil and condenser coil, 61 months in total. Warranty service and product registration run through Wine Guardian.

Find the Right Water-Cooled Cooling Unit

Compare the full water-cooled range or talk to us about whether your water loop can carry the D025WC. This guidance is general and is meant to help narrow the selection; final sizing, installation design, water-loop capacity and electrical requirements should be confirmed with Wine Guardian documentation and a licensed HVAC professional or qualified contractor.