Wine Guardian publishes the D050 platform in a single voltage column, 115 V single phase at 60 Hz, so unlike the D088 and D200 classes there is no second voltage to choose between and every capacity and current figure below belongs to that one supply. The capacity ladder is published on the Wine Guardian ducted specifications sheet against condenser inlet air temperature, in the manufacturer's own wording, and each row is given as total and sensible capacity. Note that the ladder is measured against air at the condenser, not against entering water; Wine Guardian publishes no separate capacity table against water temperature for this line, and the water side appears instead in the sheet's Water-cooled Condenser Section (option) block. No 100°F row is printed on the sheet, so none is shown here.
ModelD050WC
SeriesSentinel Series
ConfigurationSelf-contained ducted, factory-configured integral water-cooled condensing coil and water-regulating valve
Heat rejectionTo a building water loop, no warm condenser air connections required
Condenser inlet water temperature (safe operating range)45°F to 85°F
Water supplyYear-round source required; city water not recommended by Wine Guardian
Water connectionsCopper straight tube, cooling water inlet and outlet, located on the side of the unit
Water flow rate0.60 GPM (Water-cooled Condenser Section option, D050 column, Wine Guardian ducted specifications sheet)
Water-side pressure drop0.40 PSI (same block and column)
Water connection size0.50 in outside diameter, inlet and outlet (same block and column)
Water regulating valveIntegral, factory configured; main control board carries tie-in points for geothermal pumps
Manufacturer rated capacityUp to 6,320 BTU/h, rated at 80°F ambient, as published by Wine Guardian for the D050WC
Published measurement conditionNet cooling capacity at entering temperature and humidity conditions of 57°F and 55% RH at rated airflow; reduce capacity by 3% for each 10% reduction in evaporator airflow
Net cooling at 60°F condenser inlet air6,920 BTU/h total, 4,920 BTU/h sensible, at 115 V
Net cooling at 70°F condenser inlet air6,570 BTU/h total, 4,740 BTU/h sensible, at 115 V
Net cooling at 80°F condenser inlet air6,320 BTU/h total, 4,510 BTU/h sensible, at 115 V
Net cooling at 90°F condenser inlet air5,860 BTU/h total, 4,230 BTU/h sensible, at 115 V
Net cooling at 110°F condenser inlet air4,865 BTU/h total, 3,820 BTU/h sensible, at 115 V
Net cooling at 120°F condenser inlet air4,585 BTU/h total, 3,590 BTU/h sensible, at 115 V
Recommended cellar volume650–3000 ft³, as published by Wine Guardian
Storage temperature range55°F to 58°F
Humidity (with optional humidifier)55% to 65% relative humidity
Control accuracy±1°F / ±10% RH
RefrigerantR-134A
Electrical115/1/60, single voltage only
Line frequency60 Hz
Current draw (cooling)11.3 A at 115 V
Minimum circuit ampacitySee the Wine Guardian ducted specifications sheet; have a licensed electrician size the circuit
Maximum overcurrent protectionSee the Wine Guardian ducted specifications sheet; have a licensed electrician size the protection
Electric heat optionSee the Wine Guardian ducted specifications sheet; have a licensed electrician size the circuit
Evaporator fan motor100 W
Evaporator airflow390 CFM at 115 V, free blow
Dimensions (L x W x H)41.5 in x 22.5 in x 19 in
Weight125 lbs
Condensate drain connection0.50 in
Minimum ductwork size10 in round
Agency approvalUL 1995 / CSA C22.2
Cabinet constructionAluminum chassis with UL-rated composite panels
Minimum circuit ampacity, maximum overcurrent protection and the electric heat rating are printed on the Wine Guardian ducted specifications sheet as combined heat and no-heat values inside single cells and are not reproduced here. Take them from that sheet and have a licensed electrician size the circuit, the disconnect and the overcurrent protection. Condenser fan wattage is not shown either: the D050WC rejects its heat to the water loop, not to a condenser air stream.